All Collections
Manuals
Manual: Ingeteam
Manual: Ingeteam

On this page you will find the steps to connect the Ingeteam charger to the E-Flux by Road platform.

Stef van der Meer avatar
Written by Stef van der Meer
Updated over a week ago

Configuration Requirements

  • Configuration package E-Flux by Road

    • Contains: Sim card (optional), EVSE ID, configuration manual for the installer and registration manual for the owner of the charging station

  • MANUAL USUARIO INGETEAM WEB MANAGER (002).pdf

  • Configuration device: laptop/mobile phone

  • UTP cable

Follow the steps

Step 1: Use the Online installation guide, WEB manager videos and the WEB manager manual to savely complete the installation of the Ingeteam charger. The WEB manager videos and manual will also help you set up an OCPP connection.

Step 2: A local connection is required to configure the unit for the first time. Once this first configuration has been carried out, a remote connection can also be established. To establish a local connection, the charger and computer must be connected to the same communication network. The local connection can be done through an Ethernet or Wi-Fi network:

  • Ethernet:

    • Connect the computer to the unit using one of the available Ethernet connectors (J17 or J18)

    • On the computer, open the web browser and open “http://serialNumber.local:8080”, where “serialNumber” corresponds to the unit's serial number (for example, http://6S0A182A0001.local:8080). The serial number is the unit's unique identification and is located on the specifications plate

    • Enter the username and password. The username and password are specified on the documentation delivered with the unit

    • Follow the instructions given by INGEREV WEB Manager

Note: Certain operating systems may reject the above URL due to their settings. In these cases, proceed as follows:

  1. Connect the laptop computer to the unit's J17 or J18 connector using an Ethernet cable

  2. In a web browser access http://192.168.1.33:8080

  3. Follow the steps given in the browser to carry out the configuration process.

  • Wi-Fi

    • Connect the device to the network created by the charger. The network name will be the same as the unit's serial number. The Wi-Fi network password is the first 8 digits of the password specified on the sticker on the documentation delivered with the unit

    • On the device, open the browser and open http://192.168.2.1:8080 or http://SerialNumber.local:8080

    • Enter the username and password. The username and password are specified on the documentation delivered with the unit

    • Follow the instructions given by INGEREV WEB Manager

Step 3: First you have to go to ChargingPlants > SerialNumber > Network.

  • You click on edit in the wan column , then you will see the following.

    Schermafbeelding3.png

Step 4: On this page you should put your the APN: ''m2m.services'' and be sure that the discover APN is not selected.

Step 5: Go to the OCPP settings of the charger in the INGEREV WEB Manager and click on “General Settings”.

Step 6: Choose OCPP version “1.6”, fill in the E-Flux by Road server URL: “ws://ocpp.e-flux.nl/1.6/e-flux/” and click on “Save & Apply”.

Disclaimer: You must be sure that there is no space at the end of any text that you insert in our charger because it will not connect as it will consider it a different URL.

Schermafbeelding1.png

Step 7: Go to Charging Points, select the charging station and click on Status.

image-20240118-092848.png

Step 8: On the status page of the charger, you will be able to check if the OCPP connection is online or offline as shown in the screenshot below.

image-20240118-093051.png

If you are the installer of the charging station, go to Step 9. If you are the owner of the charging station, go to step 10.

Step 9: Complete the following steps to activate the station on the E-Flux by Road platform:

  1. Login to your Field Service Account or create a Field Service Account via www.e-flux.io/installer-signup*.

  2. Go to “Setup New EVSE” in the menu on the left and enter the serial number or OCPP ID of the station.

  3. Click on “Setup charging station”.

  4. Click on Upload Configuration, then click Next.

  5. Choose and define the connector type, and choose “Save Connector Configuration”.

  6. The charging station is now activated and ready to be registered by the owner!

*A Field Service Account is for installers only and will be used as a point of contact for technical tickets.

Step 10: Complete the following steps to register the station on the E-Flux by Road platform:

  1. Ask your installer to complete Step 7 to finish the configuration of your charger, or call E-Flux by Road to finish the configuration.

  2. Create an E-Flux by Road account by going to www.e-flux.io/signup.

    • Is this charging station facilitated by your employer? Check your email for the invitation.

  3. Follow the steps to add the location and register your charging station.

  4. Put the sticker with the QR code on the charging station so it’s easier to identify the station if you need support.

  5. The charging station is now registered and ready to be used!

The charging station is now connected to the E-Flux by Road platform!


Did this answer your question?