Skip to main content
All CollectionsManuals
Manual: Nidec AC Tower
Manual: Nidec AC Tower

On this page you will find the steps to connect the Nidec AC Tower charger to the E-Flux by Road platform.

Jochem Boot avatar
Written by Jochem Boot
Updated over 3 months ago

Configuration Requirements

  • Configuration package E-Flux by Road

    • Contains: Sim card (optional), EVSE ID, configuration manual for the installer and registration manual for the owner of the charging station

  • Installation manual DirectPowerPS AC Tower

  • Configuration device: laptop

  • Simcard or ethernet cable

Follow the steps

Step 1: In order to make changes to the configuration of the charging station, the web-based configuration interface must be accessed. The web interface can be accessed via USB or Ethernet:

  • USB:

    • Connect a USB cable (USB-A to micro-USB) from your PC to the controller of the charger.

    • Make sure to plug the micro USB connector of the cable into the corresponding port on the controller (marked with CONFIG).

    • Open your browser and enter the following address: http://192.168.123.123/operator

  • Ethernet:

    • Connect an ethernet cable from your PC to the controller of the charger.

    • Configure your PC to an IP address in the same range as the charger:

      • IP address: 192.168.124.100

      • Subnet Mask: 255.255.255.0

    • Open your browser and enter the following address: http://192.168.124.123/operator

Step 2: Once you have access to the web interface of the charger, you can login with the following credentials:

  • Username: operator

  • Password: yellow_zone

Note: After logging into the interface, you should immediately change the standard password of the charger to your own unique password.

Step 3: Go to the Network submenu to establish a network connection.

  • Automatic (DHCP): the IP address is automatically assigned to the charging point by the DHCP server in the network.

  • Static: The IP address of the charging point can be assigned statically.


Step 4: Navigate to the Backend submenu to setup the backend connection. Enter the following value to connect the charger to the E-Flux by Road backend:

  • OCPP ChargeBoxIdentity: enter the unique serial number of the charger

  • OCPP Mode: OCPP-J 1.6

  • WebSockets JSON OCPP URL of the Backend: ws://ocpp.e-flux.nl/1.6/e-flux

Step 5: Check in the Dashboard submenu if the charger is successfully connected to the E-Flux by Road backend.

If you are the installer of the charging station, go to Step 6. If you are the owner of the charging station, go to step 7.

Step 6: Complete the following steps to activate the station on the E-Flux by Road platform:

  1. Login to your Field Service Account or create a Field Service Account via http://www.e-flux.io/installer-signup *.

  2. Go to “Setup New EVSE” in the menu on the left and enter the serial number or OCPP ID of the station.

  3. Click on “Setup charging station”.

  4. Click on Upload Configuration, then click Next.

  5. Choose and define the connector type, and choose “Save Connector Configuration”.

  6. The charging station is now activated and ready to be registered by the owner!

*A Field Service Account is for installers only and will be used as a point of contact for technical tickets.

Step 7: Complete the following steps to register the station on the E-Flux by Road platform:

  1. Ask your installer to complete Step 6 to finish the configuration of your charger, or call E-Flux by Road to finish the configuration.

  2. Create an E-Flux by Road account by going to www.e-flux.io/signup.

    • Is this charging station facilitated by your employer? Check your email for the invitation.

  3. Follow the steps to add the location and register your charging station.

  4. Put the sticker with the QR code on the charging station so it’s easier to identify the station if you need support.

  5. The charging station is now registered and ready to be used!

The charging station is now connected to the E-Flux by Road platform!


Did this answer your question?